Intro
- The Offline Run Quality Database
was queried for the quality flag "BAD" for the detector/ID groups of CAL, CFT, Jet/MET & SMT.
- More information can be found on the
D0 Data Quality web page.
- Lists of bad runs culled from the full set of physics runs from 19 April 2002 to the present
(Runs >= 151817)
have been generated separately. These lists need to be reviewed periodically as:
- More physics runs are recorded and reconstructed
- Better discriminating algorithms are used to select bad runs
- New corrections are applied to data to minimize bad runs
This section was last modified on Thu Jan 27 07:38:59 CST 2005.
|
Combined CAL+CFT+SMT bad run list and
macro through all physics run range.
Combined CAL+CFT+L1CAL+SMT bad run list and
macro through all physics run range.
Combined CAL+CFT+L1CAL+SMT bad physics run list. Removed non-physics runs which data quality convenors are putting in the Run Quality database.
fill_badruns script that I used to make the combined lists and macros.
|
|
CAL
This section was last modified on Thu Jan 27 07:38:59 CST 2005.
|
See the
Calorimeter Data Quality web page maintained by Viatcheslav Shary and Laurent Duflot.
|
|
CFT
This section was last modified on Thu Jan 27 07:38:59 CST 2005.
|
The Tracker & Preshower data quality is
monitored by Marj Corcoran.
|
CalJetMet
- Data quality is analyzed at the resolution of Luminosity Block Numbers (LBN). Pass1 is without t42; Pass2 is with t42.
- pass1 for Run Range 151817-196584
last updated 15 October 2004.
- pass2 for Run Range 151817-196584
last updated 15 October 2004.
This section was last modified on Thu Jan 27 07:38:59 CST 2005.
|
cal_event_quality is used to identify: "ring of fire", "coherent noise" and "empty crate" events.
|
L1CAL
- The L1 Calorimeter trigger only had coverage up to abs(eta) < 0.8
for Runs 151816-157712. There are only 24 runs in this range NOT already
flagged as CAL or CFT or SMT bad runs.
- Descending List of L1 Cal Trigger Bad Runs
- Root Macro function with L1 Cal Trigger Bad Runs
This section was last modified on Mon Nov 29 09:12:34 CST 2004.
|
|
|
SMT
This section was last modified on Thu Jan 27 07:38:59 CST 2005.
|
2003-06-18: See the Beaune Workshop presentation given by Harald Fox on
SMT Quality Monitoring.
|